ULTRALOW LOSS POWER SPLITTERS BASED ON SHAPE OPTIMIZATION METHOD

Method for zeroing an optical power meter

Method for zeroing an optical power meter

EXFO can help save both time and costs with an automated calibration test system that is designed for the verification of power meters, attenuators, sources and optical time-domain reflectometers (OTDRs). This application note demystifies how EXFO's IQS-12002 Optical Calibration System can guide. An optical power meter is the most common type of test equipment used to support fiber optic system. These measurements are accomplished using either collimated-beam or connectorized-fiber.

Read More
Standard for Splice Loss in Power Optical Cables

Standard for Splice Loss in Power Optical Cables

It describes suitable procedures for splicing that should be carefully followed in order to obtain reliable splices between single optical fibres or ribbons. The Optical Time Domain Reflectometer (OTDR) will be used to test splice loss and to conduct span analysis. This is a good page to bookmark on your smartphone, tablet and/or laptop to have for making calculations in the field. Splice loss refers to the part of the optical power that is not transmitted through the splice and is radiated out of the fibre.

Read More
How much power loss is normal for an optical power meter

How much power loss is normal for an optical power meter

A typical OPM is linear from about 0 dBm (1 milli Watt) to about -50 dBm (10 nano Watt), although the display range may be larger. Above 0 dBm is considered "high power", and specially adapted units may measure up to nearly + 30 dBm ( 1 Watt). Irrespective of power meter specifications, testing below about -50 dBm tends to be sensitive to stray ambient light leaking into fibers or connectors. To be able to judge whether a fiber optic cable plant is good, one does a insertion loss test with a light source and power meter and compares that to an estimate of what is a reasonable loss for that cable plant. This is not normally an issue, since the test wavelength is usually known, but has some drawbacks. Firstly, the user must set the meter to the correct test wavelength, and secondly, the presence of spurious wavelengths can result in wrong readings.

Read More
Standard grounding connection method for enterprise power distribution boxes

Standard grounding connection method for enterprise power distribution boxes

Attach a ground wire from one of the threaded studs (A) at the bottom of the housing, to the mounting plate (B). Abstract: Discussed in this recommended practice is the system grounding of industrial and commercial power systems. For commercial and industrial systems, the types of power sources generally fall into four broad categories: Utility Service: The system grounding is usually determined by the secondary winding configuration of the upstream utility substation transformer. During the manufacturing process, metal enclosures typically have fixed points welded to the base plate or side walls.

Read More