UBIQUITI UNIFI USW AGGREGATION HIGH PERFORMANCE 10G

South Africa Aggregation Switch 10G

South Africa Aggregation Switch 10G

The Ubiquiti UniFi Aggregation Switch is a powerful networking solution ideal for South African businesses seeking reliable high-speed connections. It provides eight 10G SFP+ ports, making it a suitable core for aggregating multiple switches and devices in your UniFi network deployment. This rack-mountable switch also offers 160 Gbps switching capacity and features a 1.

Read More
Optical cables are resistant to high and low temperatures

Optical cables are resistant to high and low temperatures

Explore how to select the right fiber optic cable for challenging environments including high temperatures, extreme cold, salt spray, humidity, underground ducts, and direct burial. Learn about ADSS, OPGW, GYTA53, LSZH, and more—compliant with IEC, IEEE, UL, and. Optical fiber's ability to withstand extreme heat and cold directly impacts signal integrity, network reliability, and maintenance costs, especially in harsh environments like industrial facilities, outdoor installations, and data centers. Non-metallic, UV-proof, and temperature resistance from -40°C to +70°C. OPGW (Optical Ground Wire) integrates function of grounding with fiber communication. Harsh heat can degrade normal fiber optic cables, causing downtime, data loss, or expensive replacements. From the first works dealing with the optimization of optical fibres transmission characteristics to accommodate long distance data transmission, realized by Charles Kao (Nobel Prize of Physics in 2009), until the. Higher temperatures tend to increase the attenuation due to alterations in the glass's refractive index.

Read More
Customized Indoor High and Low Voltage Electrical Complete Sets of Equipment

Customized Indoor High and Low Voltage Electrical Complete Sets of Equipment

This solution covers a complete set of power equipment from low-voltage distribution cabinets, high-voltage switchgear to transformers, automation control systems, etc. , aiming to provide comprehensive and customized power solutions for various users. 5 Metal-clad AC draw-out switchgear is designed by Xi'an High Voltage Apparatus Research Institute and developed by Shanghai Delixi Group Co. Our high and low voltage complete electrical equipment solutions are designed based on a deep understanding of the current development trends in the power industry and accurate predictions of future power demand.

Read More
Selection of Busbar Current Carrying Capacity for High Voltage Switchgear

Selection of Busbar Current Carrying Capacity for High Voltage Switchgear

Professional busbar sizing calculator with current-carrying capacity per IEC 61439, temperature rise analysis, short-circuit withstand (thermal & mechanical), skin/proximity effect derating, voltage drop, bolted joint analysis, and copper vs aluminum cost comparison. Here are the key technical parameters considered in sizing: Rated Current (Ir): Continuous current the busbar must carry without exceeding permissible temperature rise. The current rating is calculated from the conductor cross-sectional area, material (copper or aluminium), and maximum. Undersized busbars are one of the leading causes of switchgear failures: they overheat, degrade insulation, and can trigger cascading short circuits. Busbar sizing by current and temperature rise is therefore not a formality — it is a safety-critical engineering process governed by IEC 61439-1 and. This guide is written for engineers, EPC teams, and procurement managers who need clear equipment decisions, RFQ details, and commissioning checks.

Read More
How to deal with high optical attenuation in a beam splitter

How to deal with high optical attenuation in a beam splitter

You guessed it—the solution here is to balance the reference and sample beams so that the detector must discharge less light from the reference beam before measuring the sample. Beam splitters are optical devices that play a crucial role in various scientific and industrial applications. High-End Cary UV-Vis-NIR spectrophotometers continuously ensure optimal measurement conditions by measuring the reference beam, sample beam, then dark signal (i. , the detector's natural reading in absence of all light) 30 times a second using an optical chopper. Why do we measure the beam attenuation? Related to concentration of suspended particulate and dissolved materials. Depending on the method chosen, one may suffer from thermally introduced beam distortions, interference effects, spatial inhomogeneities, or unwanted beam offsets.

Read More

Get In Touch

Connect With Us

📱

Poland (Sales & Engineering HQ)

+48 22 538 72 19

🇪🇺

Germany (EU Technical Support)

+49 30 983 21 44

📍

Headquarters & Manufacturing

ul. Postępu 14, 02-676 Warszawa, Poland