TYPES OF PROTECTION PRIMARY PROTECTION BACK UP

The leakage protection device in the primary distribution box does not trip

The leakage protection device in the primary distribution box does not trip

If the circuit breaker does not trip, or the earth-leakage indicator does not change to yellow, check that the circuit breaker is energized. If the circuit breaker is energized correctly, and has not tripped or indicated the earth-leakage fault, replace the MicroLogic4 trip unit. The first reason is that the design configuration is different The design principle of the distribution system is to realize the step-by-step protection from the standard distribution. The leakage protection device works on the basis of leakage current detection, which is an effective safeguard measure for electric power at present. Therefore, it is of great significance to find the leakage position quickly and accurately, and deal with it in time.

Read More
Protection distance of primary distribution box

Protection distance of primary distribution box

The horizontal distance between switchbox and fixed electrical equipment should not exceed 3m. Such protection relays are known as "distance protection relays" and only function in case of faults that occur between the location of the protection relay and the chosen reach point. The aim of this technical article is to cover the most important principles of four fundamental relay protections: overcurrent, directional overcurrent, distance and differential for transmission lines, power transformers and busbars. Distance relay R1 has to provide primary protection to line AB and back up protection to lines BC, BD and BE.

Read More
Fault Types of Circuit Relay Protection

Fault Types of Circuit Relay Protection

Protective Relay Definition: A protective relay is an automatic device that senses abnormal conditions in electrical circuits and triggers actions to isolate faults. Numerical Relays: Digital relays that use microprocessors, offering advanced protection and monitoring features. Based on Function Overcurrent Relay: Operates when current exceeds a preset limit. Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor technology protect staff and plant facilities for many years. IEEE Std 242 - 2001 IEEE Buff Book–IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems IEEE Std C37.

Read More
What types of optical communication protection equipment are there

What types of optical communication protection equipment are there

OCP is a protection mechanism based on optical routers, designed to safeguard individual optical channels or wavelengths. Optical line protection protects line fibers between sites using diverse routes and the dual fed and selective receiving function of the optical line protection (OLP) board. The key characteristics are small insertion losses, fast switching, and secondary. In optical networks, optical add drop multiplexers are connected through optical fiber cables.

Read More
Relay protection lact1

Relay protection lact1

The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current,, reverse flow, over-frequency, and under-frequency.

Read More

Get In Touch

Connect With Us

📱

Poland (Sales & Engineering HQ)

+48 22 538 72 19

📍

Headquarters & Manufacturing

ul. Postępu 14, 02-676 Warszawa, Poland