PRIMARY SIDE PROTECTION OF DISTRIBUTION SUBSTATION

Protection distance of primary distribution box

Protection distance of primary distribution box

The horizontal distance between switchbox and fixed electrical equipment should not exceed 3m. Such protection relays are known as "distance protection relays" and only function in case of faults that occur between the location of the protection relay and the chosen reach point. The aim of this technical article is to cover the most important principles of four fundamental relay protections: overcurrent, directional overcurrent, distance and differential for transmission lines, power transformers and busbars. Distance relay R1 has to provide primary protection to line AB and back up protection to lines BC, BD and BE.

Read More
The leakage protection device in the primary distribution box does not trip

The leakage protection device in the primary distribution box does not trip

If the circuit breaker does not trip, or the earth-leakage indicator does not change to yellow, check that the circuit breaker is energized. If the circuit breaker is energized correctly, and has not tripped or indicated the earth-leakage fault, replace the MicroLogic4 trip unit. The first reason is that the design configuration is different The design principle of the distribution system is to realize the step-by-step protection from the standard distribution. The leakage protection device works on the basis of leakage current detection, which is an effective safeguard measure for electric power at present. Therefore, it is of great significance to find the leakage position quickly and accurately, and deal with it in time.

Read More
Residual current protection test of secondary distribution box

Residual current protection test of secondary distribution box

This document gives guidance to licensed electrical workers (LEWs) and licensed electrical inspectors (LEIs) on how to meet the testing requirements in AS/NZS 3000 Electrical installations (Wiring Rules) for RCDs and RCBOs that are part of new electrical installations which are yet. An RCD is a protective device used to automatically disconnect the electrical supply when an imbalance is detected between live conductors. The Residual Current Circuit Breaker (RCCB), often known as a circuit breaker, is an electrical safety device that switches. The permanently installed PQI-DE measuring device offers many advantages over classic RCM measuring techniques on the market, in addition to the core tasks of disturbance fault recording and power quality monitoring according to EN 50160 and IEC 61000-2-4, also for monitoring the conducted EMC. In this article, we will delve into the importance of testing RCDs in accordance with EN 62423 Residual Current Protective Devices.

Read More
Wiring of the fire protection module in the distribution box

Wiring of the fire protection module in the distribution box

This publication shows how to wire and install the 4010-9825 24V Distribution Block into a 4010 Fire Alarm Control Panel (FACP). The correct wiring method is crucial for ensuring the normal operation of the fire security system. When used in a Style 4 circuit, placing devices in several branches after 8709 modules, a short in the wiring. This guide aims to demystify these diagrams, offering a deep dive into their components, functionality, and practical applications. Install this product in accordance with NFPA 72, NFPA 70, and NEC 70 and all local codes.

Read More