FATO IP65 ABS EARTH LEAKAGE PROTECTED DISTRIBUTION BOX

The leakage protection device in the primary distribution box does not trip

The leakage protection device in the primary distribution box does not trip

If the circuit breaker does not trip, or the earth-leakage indicator does not change to yellow, check that the circuit breaker is energized. If the circuit breaker is energized correctly, and has not tripped or indicated the earth-leakage fault, replace the MicroLogic4 trip unit. The first reason is that the design configuration is different The design principle of the distribution system is to realize the step-by-step protection from the standard distribution. The leakage protection device works on the basis of leakage current detection, which is an effective safeguard measure for electric power at present. Therefore, it is of great significance to find the leakage position quickly and accurately, and deal with it in time.

Read More
Size of leakage current switch in distribution box

Size of leakage current switch in distribution box

Frame rated current of leakage release is 63A, can be connected to the wire of 10mm² and 25mm². The leakage protection switch is suitable for the circuits of AC 50Hz, rated voltage of 230V ~ 400V, rated current of 63A, mainly consists of the zero-sequence current transformer, electronic components board, leakage circuit breakers. Leakage current refers to the unintentional flow of electric current between an energized conductor and any other conducting surface or material. Sigma Illegal Current Protection switches save lives, protects from fire Illegal current protection switches are protective electrical equipment that should be used against electric leaks that risk life and property safety.

Read More
The fiber distribution box can be easily repositioned

The fiber distribution box can be easily repositioned

The Fiber Optic Distribution Box features a convenient flip-up design, facilitating effortless fiber management during installation. The individually installed splicing trays can be easily repositioned as necessary. With a maximum capacity of 24 cores, it has the capability to splice up to 48 cores. The 2LINE product range is rounded off by wall distributors, fibre optic termination points and subscriber connection boxes, which can be used in all projects in both subsidised and self-supported expansion.

Read More
How many meters long is the lightning protection grounding of the optical distribution box

How many meters long is the lightning protection grounding of the optical distribution box

In pole groundings, lightning protection wires are needed every 250 meters between the poles. Our light-ning and surge voltage protection systems are per-fectly matched to one another and to the requirements in the different zones – from the air-termination device, which must arrest the full energy of a lightning strike, through to fine power protection, which eliminates the last voltage. Lightning protection and grounding design for a car service station having dimensions 30. Values up to 25 ohms may be acceptable in some cases, but lower is always better.

Read More