Communication devices in the relay protection room
Let's start with brief description of seven most known and most used communication medias used in power system communications (in terms of protection and automation):.
Read More
Let's start with brief description of seven most known and most used communication medias used in power system communications (in terms of protection and automation):.
Read More
Relay protection is the discipline of designing schemes that detect faults, coordinate relays, and isolate equipment without outages. Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions.
Read More
This guide focuses primarily on application of protective relays for the protection of power transformers, with an emphasis on the most prevalent protection schemes and transformers.
Read More
Abstract−To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a. For those not familiar with the different elements that form a WEP, commonly known as a Wind Farm, this report introduces a description of the different elements comprising a wind farm and how their unique characteristics may be considered to provide a proper design. First, the amplitude and attenuation characteristics of short circuit current in different types of wind turbines are analyzed, as well as the contributing factors to short-circuit current in wind farms. Protection of Wind Electric Plants is a report covering engineering considerations for the design of protection systems and present relay protection and coordination practices at wind electric plants. Abstract—A wind electric plant (WEP) is made of many wind turbine generators spread over a large area and includes many subsystems that need to be protected.
Read More
Vertical shutters (like fire rated rolling shutters) may also be acceptable provided they are combined with a single leaf door opening outwards for exit in case of emergency. • Switchroom doors must open outward without needing a key or tool from the switchboard side to ensure quick evacuation. The quantity of entrances required is dependent upon the ampere rating and width of the equipment, however the code never requires more than two entrances.