AISLE CONTAINMENT SYSTEMS FOR 600 MM RACKS EATON

Hot aisle containment system for computer room

Hot aisle containment system for computer room

Hot aisle containment consists of a physical barrier that guides hot exhaust airflow back to the AC return. Essentially creating a room within the aisle, the system helps keep hot and cold air separated to make existing air conditioning systems in data center and edge-of-network.

Read More
Cool aisle ventilation direction for server racks

Cool aisle ventilation direction for server racks

Cold air is directed to the front of server racks, while hot air released from the back is removed. Raised floors are commonly used in data centers to provide an efficient way to deliver cold air from the computer room air conditioner (CRAC) unit to server racks. Improve server rack airflow and efficiency with practical strategies like hot aisle–cold aisle layout, blanking panels, cable management, proper spacing, and cooling. Cold air is delivered into this aisle through: Servers pull this cold air into their front. This configuration is beneficial as it will conserve energy and lower cooling costs by directly managing air flow.

Read More
What size square mm grounding wire should be used for network server racks

What size square mm grounding wire should be used for network server racks

122 is the primary reference for determining the minimum size of equipment grounding conductors based on the rating of the overcurrent protection device. The National Electrical Code (NEC) provides clear guidelines for ground wire sizing through Table 250. 122, but understanding how to apply these requirements correctly can make the difference between a safe installation and a costly code violation.

Read More
What to put in data center network racks

What to put in data center network racks

In this article, we will explore the various components that you should consider placing in your server rack. A good home server rack organizes your hardware, keeps cables under control, and improves airflow. This guide shows you exactly what to install in your rack and how to build a clean, reliable setup at home. A data center server rack is the physical foundation of modern IT infrastructure, enabling the organized installation of servers, switches, PDUs, UPS systems, and structured cabling. Modern businesses depend on data, with data centres serving as the engine rooms powering digital transformation, AI, and cloud platforms. Welcome to the world of server racks! If you are setting up a data center, a server room, or even a small home office, a server rack is an essential piece of equipment to house your server and networking infrastructure.

Read More
Waterproofing and safety measures for network server racks

Waterproofing and safety measures for network server racks

Learn effective strategies to safeguard server racks from water damage, including tips on placement, sensors, and flood prevention techniques. Imagine walking into your server room, only to find equipment soaked from an unexpected leak or a minor flood. This article provides a comprehensive guide to waterproof enclosure design, with a particular focus on server chassis applications. NEMA 12 enclosures are constructed for indoor use and provide a degree of protection to internal equipment against circulating dust, falling dirt, lint, and fibers. Built to NEMA 4X from stainless steel, Armagard's Waterproof Rack Mount Cabinet can safely house conventional rack-mountable equipment up to a maximum capacity of 18U.

Read More

Get In Touch

Connect With Us

📱

Poland (Sales & Engineering HQ)

+48 22 538 72 19

🇪🇺

Germany (EU Technical Support)

+49 30 983 21 44

📍

Headquarters & Manufacturing

ul. Postępu 14, 02-676 Warszawa, Poland