5 ESSENTIAL ELEMENTS FOR SAFE AND ON TIME DELIVERY OF

Delivery time of upgraded German splice box

Delivery time of upgraded German splice box

German production facilities maintained delivery times of 2-4 weeks, whilst Asian imports sometimes required 16-20 weeks lead time. The flexibility of German manufacturers is particularly evident in project-specific. Splice boxes and splice distributors are essential for a reliable fiber optic cabling system and serve as a connecting point between the fiber optic installation cable and the in-house network. We have been working for our customers throughout Germany and in the neighbouring German-speaking countries since 1999. Applications: FTTH, FTTB, data centers, government agencies, industrial automation Features:.

Read More
Relay protection differential coordination time

Relay protection differential coordination time

The IEC standard for relay coordination recommends time grading between relays based on fault current magnitude and operating characteristics. Selective short-circuit protection can be achieved in different ways, such as: Time-graded protection Time- and current-graded protection A straightforward way of obtaining selective protection is to use time grading. System Configuration Source Short Circuit MVA (at PCC) Short circuit capacity of the upstream source at the point of common coupling. Achieving coordination and ensuring that time overcurrent and distance relays operate in a predictable manner can be quite burdensome, especially in highly coupled power systems with tight loops in the topology structure. The faster the protection operates, the smaller the resulting hazards, damage and the thermal stress will be.

Read More
220kV relay protection operating time

220kV relay protection operating time

For high fault resistance ground faults, the operating time of the protection is usually stepped from m 1–3 seconds and operating times are harmonised with the protection of the main grid. The 110 and 220 kV lines of the main grid are protected by means of two primary protection schemes (two distance relays or a distance and a differential line relay) or a primary protection relay (distance relay) and a backup protection relay (overcurrent and earth fault relay). Time-graded protection is implemented using overcurrent relays with either definite time characteristic or inverse time characteristic. The numerical terminals referred as IED (Intelligent electronic device) contain apart. In case of Long Line, followed by Short Line, the above mentioned Formula may not give us margin against possible underreaching. Inverse time delay, on the other hand, depends on the current magnitude so, the higher the current, the shorter the delay.

Read More